d-Color MF4003/MF3303
L TROUBLESHOOTING > 2. MALFUNCTION CODE
L-16
2. MALFUNCTION CODE
2.1 Display procedure
• The machine's CPU performs a self-diagnostics function that, on detecting a malfunction, gives the corresponding malfunction code and
maintenance call mark on the control panel.
• Touching the maintenance call mark will display the corresponding malfunction code on the state confirm screen.
2.2 List of the malfunction code
• If an image stabilization or scanner fault occurs, the corresponding malfunction code appears.
Malfunction code
Contents
S-1
CCD gain adjustment failure
P-5
IDC sensor failure
P-6
Imaging unit (C) failure
P-7
Imaging unit (M) failure
P-8
Imaging unit (Y) failure
P-9
Imaging unit (K) failure
P-21
Color regist test pattern failure
P-22
Color regist adjust failure
P-33
LD malfunction
2.3 S-1
Contents
Malfunction type
CCD gain adjustment failure
Malfunction code
S-1
Malfunction detection timing
It is detected that the CCD clamp gain adjustment value is faulty.
Relevant parts
• CIS module (IR CIS)
• Base board (BASEB)
Procedure
1.
Correct the harness connection between IR CIS-BASEB CN6 if faulty.
2.
Check for possible extraneous light and correct as necessary.
3.
4.
Service Manual
Y119930-3
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...