![Olivetti d-Color MF 4003 Service Manual Download Page 478](http://html1.mh-extra.com/html/olivetti/d-color-mf-4003/d-color-mf-4003_service-manual_3811479478.webp)
d-Color MF4003/MF3303
L TROUBLESHOOTING > 4. TROUBLESHOOTING USING SELF-DIAG. (FULL)
L-80
2.
Correct the mounting of BASEB or the connection of connectors if faulty.
3.
4.16 E5-4
Contents
Error code
E5-4
Target device
Various USB devices
Diagnosis item
USB device HUB chip (USB hub board)
Reason of error
Connection failure
Parts defect
Relevant electrical parts
USB hub board (USBHB)
Base board (BASEB)
Corrective action procedure
1.
Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2.
Correct the mounting of USBHB or the connection of connectors if faulty.
3.
Correct the mounting of BASEB or the connection of connectors if faulty.
4.
5.
4.17 E5-5
Contents
Error code
E5-5
Target device
Various USB devices
Diagnosis item
DAC-IC
Reason of error
Connection failure
Parts defect
Relevant electrical parts
USB hub board (USBHB)
Corrective action procedure
1.
Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2.
Correct the mounting of USBHB or the connection of connectors if faulty.
3.
4.18 E5-7
Contents
Error code
E5-7
Target device
Various USB devices
Diagnosis item
E5-7
FAX board (line 1)
Reason of error
Connection failure
Parts defect
Relevant electrical parts
FAX board (FAXB)
Base board (BASEB)
Corrective action procedure
1.
Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2.
Correct the mounting of the FAX board or the connection of connectors if faulty.
3.
Correct the mounting of BASEB or the connection of connectors if faulty.
4.
5.
4.19 E5-11
Contents
Error code
E5-11
Target device
Various USB devices
Diagnosis item
Upgrade kit (UK-221)
Reason of error
Connection failure
Parts defect
Relevant electrical parts
Wireless LAN board (WLANB)
Base board (BASEB)
Corrective action procedure
1.
Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
Service Manual
Y119930-3
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...