background image

6.OSD - Patterns, Tours

6.OSD - Zones and Privacy Mask

PATTERNS

Pattern

Pattern records the user’s operation steps on 
performing PTZ control and stores as a track. The 
high speed dome series can record up to 4 tracks 
with max. 180 sec. each.

PATTERN  NUMBER: 

Selects the pattern number, from 1 

to 4

PROGRAM  PATTERN: 

Starts recording the pattern 

when selected. you can perfome PTZ movement for 
recording and shall not exceed 180 sec. Press IRIS-
OPEN to save the track.

RUN  PATTERN: 

Starts the current pattern

CLEAR  PATTERN: 

Delete curretn pattern.

EDIT  PATTERN  LABEL :

 Sets the name for current 

pattern.

PATTERN  NUMBER    1
PROGRAM  PATTERN
RUN  PATTERN
CLEAR  PATTERN
EDIT  PATTERN  LABEL
BACK
EXIT

Tour

Tour is an auto-run through selected preset 
points with definable pause time. A tour can 
store up to 32 presets points.

TOUR DWELL:

 pause time for every stop on the 

preset points. selectable between 000-255(s).

TOUR PRESETS:

  press IRIS-OPEN Key on the 

keyboard device to enter the preset point 
selection. Move the joystick with up and down to 
select the preset points by number and save  the 
setting with IRIS-OPEN key.  with IRIS-CLOSE 
key you can move to the previous selection. If a 
select point has the value 0, all the following 
presets points will be ignored.

RUN TOUR:

  Starts the tour and exit the OSD 

menu.

        

  EDIT   TOUR

  

TOUR  DWELL           001
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
RUN    TOUR
BACK
EXIT

Zone

to up to 8 zones with individual label. When the 
display setting “Zone Label” is activated,  the 
label will be displayed on the operation screen. 
The definition of the zones should not be  
overlapped.

ZONES NUMBER: 

Current zone selection

SET LEFT LIMIT: 

Left limit of the current zone

SET RIGHT LIMIT: 

Right limit of the current zone

CLEAR ZONE: 

Delet the current zone

EDIT ZONE LABEL : 

change the laben of current 

zone.

You can define the zones in the whole PT range up 

ZONES

ZONES NUMBER       1
SET LEFT LIMIT
SET RIGHT LIMIT 
CLEAR ZONE
EDIT ZONE LABEL 
BACK
EXIT

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

17

18

TIME RUNNING

DAY

      SUN

  TIME CHANNEL   1
  START TIME         00:00
  END TIME 

      00:00

  RUNNING

      NONE

BACK
EXIT

Time Running

You can set up the timer to start a function like 
preset, tour or pattern. Each day can be set 4 
action.

AUTO TRACKING

DAY

      SUN

  STATE

       ON

  START TIME         00:00
  END TIME 

      00:00

SENSITIVE

      LOW

TRACKING-ZOOM OFF
SET LEFT LIMIT
SET RIGHT LIMT
BACK
EXIT

AUTO TRACKING

Auto-Tracking can seach people or object with 
high speed and low light performance.

DAY:

set current day

STATE:    activate AUTO-TRACKING on this day
START TIME: set the time for activation
END TIME: set the time for stop the tracking
SENSITIVE: set the sensitivity for the detection
TRAKING ZOOM: activate auto-zoom
SET LIMIT: set the max. angle for the tracking. 

Summary of Contents for SP27HB-V55DN

Page 1: ...OKINA High Speed Dome Camera Series USER MANUAL SP27HB V55DN SP37HB V55DN v2 61...

Page 2: ...NTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT TH...

Page 3: ...signed And do not bend or squeez the sturctiure as this may damage the mechanic sturcture of the appliance and avoids the warranty Do not touch the Cover with bare hands or any object These will scrat...

Page 4: ...t damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application whi...

Page 5: ...nology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800...

Page 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters 120 Resistor Device 2 Device 3 Device 1 120 R...

Page 7: ...fter unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please...

Page 8: ...R CUT ON TIME N A IR CUT OFF TIME N A THRESHOLD 10dB MAX GAIN 28dB EXPOSURE COMP OFF MIRROR OFF FLIP OFF BACK EXIT PRESETS SCAN SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN R...

Page 9: ...ion The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION the action which will be started after the idle time park time Selectable between Preset...

Page 10: ...supports up to 128 presets The number can be selected from 0 to 128 SET PRESET Defining the preset points directly in OSD by entering this menu item and move the PTZ press IRIS OPEN key on the keyboa...

Page 11: ...00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 RUN TOUR BACK EXIT Zone to up to 8 zones with individual label When the display setting Zone Label is activated the label will be displayed on...

Page 12: ...0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0...

Page 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135...

Page 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255...

Page 15: ...n 50 dB Object Tracking only G70AT serie Communication Preset Positions Auto Pan Tour Sequence Alarm inputs Operating Environment Power Manual activation Preset triggering Scheduled activation Trackin...

Reviews: