background image

6.OSD - Alarm Setting

Alarms

RESUME: 

Continue the function on the camera , if it

was setting before the alarms. 

RESET DELAY:

 How long the camera stay in Alarm 

position.

ALARM CONTACT:

 Setting between N/C (normal Close) 

or N/O (normal Open).

ALARM NUMBER:

 curent Alarm number.

ALARM ACTION: 

Setting for PRESET, SCAN, TOUR, 

PAT 1-4, or NONE, if the camere in Alarm position.

ACTIVATE AUX: 

Setting Alarm Output, when Alarm is 

activate. Select between AUX1,  AUX2 (not connected) 
or BOTH. 

ALARM PRIORITY: 

define the priority of the alarm input. 

ARM SETTING:

 define the operation timer of  the alarm  

7. Dome Address & Protocol

Sw1

Sw2

Protocol setting

In order to establish a connection for 
telemetric control with keyboard device. you 
need to setup the dome address and protocol.

The PTZ cameras are capable with multiple 
communication protocol. The setting can be 
changed through the DIP-Switches on the rear 
side of the connector boards as Illustrated.

please use the following table for details setup.

 current pattern.

Baud rate

DIP 7

DIP8

2400 bps

0

0

4800 bps

1

0

9600 bps

0

1

19200 bps

1

1

SW 1:
 

represent the domes address in binary form. 

please refer to the list on next page for reference.

SW 2:

Used for protocol settting and baud rate.

DIP 1 to 6 : Protocol setting
DIP 7 and 8: Baud rate setting

Protocol / DIP

1 2 3 4 5 6

B02

0 0 1 1 0 0

DIAMOND

1 0 0 1 0 0

HUNDA

1 0 1 1 0 0

KALATEL

0 1 0 1 0 0

LILIN

1 1 0 1 0 0

MOLYNX

0 0 1 0 0 0

PANASONIC

1 1 1 0 0 0

PELCO (D/P)

1 0 0 0 0 0

PHILIPS

0 0 0 0 0 1

SAE

0 1 0 0 0 0

SAMSUNG

0 0 0 1 0 0

SANTACHI

0 1 1 0 0 0

UNIVISION

0 1 0 0 0 1

VCL

1 1 0 0 0 0

VICON

1 0 1 0 0 0

AD

1 0 0 0 0 1

Some products may not be available in your country, please contact our distributor for more details

ALARM SETTING

ALARM NUMBER     001

 

ACTION     TOUR

ACTIVATE AUX     AUX1

ALARM PRIORITY   LOW

BACK

EXIT

ALARM

W I N D O W  B LANKING

WINDOW  NUMBER    01
EDIT  WINDOW
ENABLE  WINDOW    OFF
CLEAR  WINDOW
BACK
EXIT

Privacy Mask ( Window Blanking)

Privacy Mask is used to protect the privacy area not to be 
displayed once the camera is pointed on, such as 
ulevatory area or the operation desk of an ATM machine. 
It might be required for video surveillance application 
depends on the local law regulation. The PTZ camera 
supports up to 24 private masks. ( depends on installed 
camera module, please contact your local sales 
representative for more information)

Hitachi camera modules

:

 

8 masking area.

Sony Camera modules:

 

up to  24 masking area ( 

except the 45 series provides only 8)

LG,CNB Camera modules:

 

no masking function.

WINDOW  NUMBER:

 Mask number

EDIT  WINDOW: 

Edit position of the mask by joystick of 

the keyboard. presse IRIS-OPEN to save.

ENABLE  WINDOW:

 shows the mask on screen    OFF

CLEAR  WINDOW:

 Delete the mask

ALARMS

Resume                  OFF

SEQUENCE           001

RESET DELEY      030

ALARM CONTACT N/O

ALARM SETTING

ARM SETTING

BACK 

EXIT

ARM SETTING

DAY

      SUN

  ARM STATE          OFF
  ARM TIME             N/A
  UNARM TIME       N/A
BACK
EXIT

19

Summary of Contents for SP27HB-V55DN

Page 1: ...OKINA High Speed Dome Camera Series USER MANUAL SP27HB V55DN SP37HB V55DN v2 61...

Page 2: ...NTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT TH...

Page 3: ...signed And do not bend or squeez the sturctiure as this may damage the mechanic sturcture of the appliance and avoids the warranty Do not touch the Cover with bare hands or any object These will scrat...

Page 4: ...t damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application whi...

Page 5: ...nology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800...

Page 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters 120 Resistor Device 2 Device 3 Device 1 120 R...

Page 7: ...fter unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please...

Page 8: ...R CUT ON TIME N A IR CUT OFF TIME N A THRESHOLD 10dB MAX GAIN 28dB EXPOSURE COMP OFF MIRROR OFF FLIP OFF BACK EXIT PRESETS SCAN SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN R...

Page 9: ...ion The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION the action which will be started after the idle time park time Selectable between Preset...

Page 10: ...supports up to 128 presets The number can be selected from 0 to 128 SET PRESET Defining the preset points directly in OSD by entering this menu item and move the PTZ press IRIS OPEN key on the keyboa...

Page 11: ...00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 RUN TOUR BACK EXIT Zone to up to 8 zones with individual label When the display setting Zone Label is activated the label will be displayed on...

Page 12: ...0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0...

Page 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135...

Page 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255...

Page 15: ...n 50 dB Object Tracking only G70AT serie Communication Preset Positions Auto Pan Tour Sequence Alarm inputs Operating Environment Power Manual activation Preset triggering Scheduled activation Trackin...

Reviews: