4.INSTALLATION

4.INSTALLATION

Video Cable

coaxial

 

cable with 75  impedance with copper conductor at center conductor, and 

shielded with  95% copper. The following table shows different cable type and its 
maximum length:

Ω

The values are for reference only. 
Depends on the cable quality and 
environmental condition, the 
transmission distance might be less.

RG 6 /U

Cable standard

RG 11 /U

229m / 750 ft

Max. Distance (m /ft )

305m/ 1000 ft

457m / 1500 ft

RG 59 /U

If the cable length is more than 400 m, it is recommended to use optional 
accessories, such as video amlifier or twisted-pair video converter , for boost 
the video signal.

Video Amplifier
(optional)

Real time DVR Center

(optional)

High Res Monitor
(optional)

Up to 750m, coaxial cable

Extend connection distance with
video amplifier

TP receiver
(optional)

Real time DVR Center

(optional)

High Res Monitor
(optional)

Up to 1200m, twisted pair or cat.5 cable

Extend connection distance with Twisted-Pair 
video converter

 transmitter
(optional)

The PTZ cameras provide integrated termination switch. It should be turned on 
when the dome is installed as the last device. If the controller keyboard is used, 
you need also to turn on the termination on it. please refer to the keyboard’s 
manual for details.

RS-485Termination

Devices using Rs485 control are usually connected in daisy-chain. which reqiuers 
termination with 120

Ω

 resistor on both ends. Following picture illustrates the 

connection methods. please note that a daisy-chain connection type shall not 
exceed 7 meters.

120

Ω

R

esistor

Device 2

Device 3

Device 1

120

Ω

R

esistor

RS 485+

RS 485-

RS 485+

RS 485-

Termination
on

Termination 
off

Termination 
off

How to turn on termination on the high speed dome camera

The termination switch is located on the rear side of the connection board. For 
switching on, you need to open the 

Star-Connection

The star-form connection is mostly used. it enables the connection of different dome 
cameras in longer distance. It is recommended to use RS-485 distributor  to ensure the
 telemetric data transmission:

The advantage of star-connection is 
that every channel can work 
independently and take a cable 
length up to 1000 meters( depends 
on cable quality). In case more 
dome camera are installed, the star-
connection can be extended with 
additional RS-485 distributors.

Some products may not be available in your country, please contact our distributor for more details

1

2

3

Term. Off ( default)

Term. On

1

2

3

ON

ON

 

OFF

OFF

ON

ON

 

Jumper

Termination
Jumper

rear side

How to open the connector board

The connector board can be easily 
opened by holding the metal clip and 
pull. 

Press the metal
clip in and pull
the board on this
direction.

Metal
Clip holder

Some products may not be available in your country, please contact our distributor for more details

7

8

Termination on

Termination on

RS-485 
Distributor

RS-485 cable
up to 1000m 
per channel

Termination
activated on
every end.

Summary of Contents for SP27HB-V55DN

Page 1: ...OKINA High Speed Dome Camera Series USER MANUAL SP27HB V55DN SP37HB V55DN v2 61...

Page 2: ...NTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT TH...

Page 3: ...signed And do not bend or squeez the sturctiure as this may damage the mechanic sturcture of the appliance and avoids the warranty Do not touch the Cover with bare hands or any object These will scrat...

Page 4: ...t damages caused by high voltage pulse such as lightning strike below 1500 This appliance meets the Ip66 standard for water and dust proof Do not install the in door model for out door application whi...

Page 5: ...nology Depends on the cable typeand baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 4oom 4800...

Page 6: ...th 120 resistor on both ends Following picture illustrates the connection methods please note that a daisy chain connection type shall not exceed 7 meters 120 Resistor Device 2 Device 3 Device 1 120 R...

Page 7: ...fter unpaking and during the installation the core unit should be installed as following Installing the core unit by pushing into the housing please note the position of connector For releasing please...

Page 8: ...R CUT ON TIME N A IR CUT OFF TIME N A THRESHOLD 10dB MAX GAIN 28dB EXPOSURE COMP OFF MIRROR OFF FLIP OFF BACK EXIT PRESETS SCAN SCAN NUMBER 01 SCAN SPEED 63 SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN R...

Page 9: ...ion The range is from 1 to 240 minutes This function can be deactivated by setting the minute to 0 PARK ACTION the action which will be started after the idle time park time Selectable between Preset...

Page 10: ...supports up to 128 presets The number can be selected from 0 to 128 SET PRESET Defining the preset points directly in OSD by entering this menu item and move the PTZ press IRIS OPEN key on the keyboa...

Page 11: ...00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 RUN TOUR BACK EXIT Zone to up to 8 zones with individual label When the display setting Zone Label is activated the label will be displayed on...

Page 12: ...0 0 HUNDA 1 0 1 1 0 0 KALATEL 0 1 0 1 0 0 LILIN 1 1 0 1 0 0 MOLYNX 0 0 1 0 0 0 PANASONIC 1 1 1 0 0 0 PELCO D P 1 0 0 0 0 0 PHILIPS 0 0 0 0 0 1 SAE 0 1 0 0 0 0 SAMSUNG 0 0 0 1 0 0 SANTACHI 0 1 1 0 0 0...

Page 13: ...7 Address ID 1 to 67 7 Address ID 68 to 135...

Page 14: ...7 Address ID 136 to 203 177 7 Address ID 204 to 255...

Page 15: ...n 50 dB Object Tracking only G70AT serie Communication Preset Positions Auto Pan Tour Sequence Alarm inputs Operating Environment Power Manual activation Preset triggering Scheduled activation Trackin...

Reviews: