44473001TH Rev.1
115 /
Oki Data CONFIDENTIAL
4.REPLACEMENT OF PARTS
4.2.16 High-voltage power supply board
(1) Remove the right side cover and the CU/PU PCB.
(2) Remove the four (silver-colored) screws
①
to remove the film-PUCU board
②
and
the plate board
③
.
(3) Remove the two (silver-colored) screw to remove the plate-FG
⑤
.
(4) Unlatch the four portions to detach the high-voltage power supply board
⑤
.
Summary of Contents for MC561
Page 1: ...Maintenance Manual 12610B MC361 MC561 CX2731MFP...
Page 79: ...44473001TH Rev 1 79 Oki Data CONFIDENTIAL 3 MFP INSTALLATION Sample MC361 Sample MC351...
Page 93: ...44473001TH Rev 1 93 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS...
Page 109: ...44473001TH Rev 1 109 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS C C A A D B B D...