5. MAINTENANCE MENUS
Item1
Item2
Item3
Item4
Item5
Value
Default
value
ODA
Default
value
OEL
Default
value
JP
Notes
Password
ADF
(Back-side)
Adjust CIS
Adjust CIS
simple
R continuous
G continuous
B continuous
All continuous
Sequentially light the designated RGB colors and check them during calibration
configuration duties.
Move the CIS to the standard position.
In the position moved to, sequentially light R, followed by G and B in the same manner.
Light each color for approximately 3 seconds.
Display "Testing" during execution?
→
On the panel, display "CIS light testing" and "Cancel."
Check CIS
300dpi
600dpi
1200dpi
--- Results displayed ---
CCD_SIG9_WID_H 0 x 000000
CCD_SIG2_WID_H 0 x 000000
Check CIS maintenance displays the exposure time at each resolution.
When resolution is set, scanner calibration is conducted at that resolution and the
following results are displayed:
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
Note: CIS exposure time varies with resolution.
Set CIS
Exposure
time
0 ~ 4294967295
Change LED exposure time settings, and then read the document using PC Scan.
Reading implemented for the LED exposure time in the settings, without conducting
calibration.
A warning is displayed when a value greater than the Lsync cycle has been set.
Settings are shown below.
Red-1
Red-2
Green-1
Green-2
Blue-1
Blue-2
Lsync
Summary of Contents for MC561
Page 1: ...Maintenance Manual 12610B MC361 MC561 CX2731MFP...
Page 79: ...44473001TH Rev 1 79 Oki Data CONFIDENTIAL 3 MFP INSTALLATION Sample MC361 Sample MC351...
Page 93: ...44473001TH Rev 1 93 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS...
Page 109: ...44473001TH Rev 1 109 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS C C A A D B B D...