4.2.7.15 Frame-assy-FB
(1) Remove the four screws (black)
①
, remove the screw (silver)
②
.
(2) Take off two parts (Plate-FG-SU
③
/ Plate-FG-FAX
④
)
(3) Remove the cover-SU
⑤
.
(4) Remove the two screws (silver)
⑥
, remove the plate-shield-FAX
⑦
.
(5) Remove the all FAX-board cables.
(6) Remove the three screws (silver)
⑧
and remove the FAX-board
⑨
.
(7) Remove the screw (black)
⑩
, remove the two screws (silver)
⑪
.
(8) And remove the clamp-cable
⑫
.
(9) Remove the plate-FAX-board
⑬
.
(10) Remove the four screws (silver)
⑭
and remove the plate-shield-SU
⑮
.
(11) Remove the all SU-board cable (
⑯
etc).
(12) Remove the four screws (silver)
⑰
and remove the SU-board
⑱
.
(13) Remove the two screws (black)
⑲
.
(14) Remove the plate-SU-board
⑳
.
(15) Pull core x2
㉑
(SSC-40-12 (1051073C4002)) out of FFC cable.
(16) Remove the FFC cable (20706FWR1.0L-30-105)
㉒
.
(17) Remove the four screws (black)
㉓
.
(18) Remove the cover-hinge (L)
㉔
.
(19) And remove the plate-hinge-L (caulking)
㉕
.
(20) Remove the seven screws (black)
㉖
.
(21) Remove the four cam-hinge
㉗
.
(22) Remove the two screws (black)
㉘
.
(23) Remove the cover-assy-LF
㉙
.
(24) Remove the four screws (black)
㉚ and
take out a FFC-cable
(20706ASFBNCD0550-642)
㉛
wrapped in film-FFC
㉜
.
(25) Pull out FFC-cable (20706FWR1.0-16-320)
㉝
from frame-bottom.
Summary of Contents for MC561
Page 1: ...Maintenance Manual 12610B MC361 MC561 CX2731MFP...
Page 79: ...44473001TH Rev 1 79 Oki Data CONFIDENTIAL 3 MFP INSTALLATION Sample MC361 Sample MC351...
Page 93: ...44473001TH Rev 1 93 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS...
Page 109: ...44473001TH Rev 1 109 Oki Data CONFIDENTIAL 4 REPLACEMENT OF PARTS C C A A D B B D...