List of the Device Setting Menu Items
- 83 -
Config
uring
at t
h
e Oper
ator P
anel
6
Fax Setup
Default
Settings
Mixed Size
OFF
Sets whether different sized documents
are copied on each size paper as the
default.
Margin
Margin
OFF
Sets the default settings of margins.
Margin
Front
Left
0
Available rage: 0 to
±
25 mm
(0.0 to 1.0inches) (1 mm/ increment)
Top
Back
Left
Top
Edge Erase
Setting
ON
Sets whether to erase the shade created
in the surrounding of 2-page spread docu-
ments as the default.
Width
2 mm
(0.1 inch)
Sets an erasing width.
Available range:2 to 50 mm
(0.1 to 2.0 inches).
Item
Factory
Default
Description
Default
Settings
Resolution
Normal
Sets the default setting of image quality.
Density
0
Sets the default density of images.
Scan Size
A4 or Letter
Sets the default scan size.
Continue Scan
OFF
Sets whether to use the continue scan
mode.
TTI
ON
Sets whether to add the sender's name to
the header of the transmitted fax.
Transmit Confirmation Report
ON or OFF
Sets whether to print the result of the
transmission automatically.
Memory Tx
ON
Sets whether to use memory transmission
(ON) or real-time transmission (OFF).
Fcode
Box
Edit/Register
Confidential
Box
Box Name
(NULL)
Sets the name of confidential boxes. Maxi-
mum 16 characters.
Sub-Address (NULL)
Sets the sub-address for your confidential
box. Maximum 20 characters.
Hold Time
0
Sets the hold time for your confidential
box. Available range: 00 to 31 days.
I.D.Code
(NULL)
Sets the password for your confidential
document box. Four characters from 0 to
9 (numbers only).
Bulletin Box
Box Name
(NULL)
Sets a bulletin box name. Maximum 16
characters.
Sub-Address (NULL)
Sets a sub-address for your bulletin box.
Maximum 20 characters.
Delete
Deletes an Fcode box.
Security
Function
ID Check Tx
OFF
Sets whether to use the ID check trans-
mission.
Broadcast Destination
ON
Sets whether to indicate the destination
number before starting broadcast trans-
mission.
Confirm Dial
OFF
Sets whether to reenter the destination
fax number before sending a fax.
Item
Factory
Default
Description