Oki Data CONFIDENTIAL
44158801TH Rev.2
221 /
Table 8-1-2 Service Call Error (6/7)
Message
Cause
Error Description
Solution
Service call
220:Error
False setting of
a record medium
detected by a print
statistics.
Take off the HDD or replaced?
Yes
Reset original HDD.
Service call
230:Error
RFID Reader not
Installed
RFID read device error
Is the error issued again?
Yes
Yes
Check the connection of
the RFID R/W board.
Replace the RFID R/W
board.
Replace the S2V PCB.
Service call
231:Error
RFID Reader I/F
Error
An interface error was detected with
the RFID reader device.
01: communication error between
the RFID reader and the engine
PCB.
02: the transceiver circuit error of
the RFID reader.
03: communication error between
the RFID reader and the toner
cartridge.
04: the toner cartridge detection
error (more than 4).
01: Same as Error 230
02: Replace RFID R/W
board.
03: Check the antenna
cable connection.
04: Check to see if
the quantity of toner
cartridge is correct.
Service call
250:Error
Secure File Erasing
Error
An erasing error of an encrypted file
was detected.
Did the user agree to execute HDD
ERASE?
Notify the user that Disk
ERASE needs to be
executed to erase the
encrypted file, so that the
HDD is restored to the
original state as at the
time of purchase. ADMIN
MENU HDD ERASE
Service call
251:Error
Secure Disk
Erasing Error
An error was detected during Disk
ERASE.
Can the error indication be
reproduced?
Yes
Turn the power off and on
again.
Replace the HDD.
Power off/on
901:Error
902:Error
Short or open in
belt thermistor
detected.
Is belt thermistor cable setting
proper?
Does error reoccur?
No
Yes
Yes
Connect cable set
properly again.
Turn power ON again.
Replace belt thermistor.
Power off/on
903:Error
904:Error
Abnormal
temperature
detected by belt
thermistor (high-
temp or low temp.)
Is belt thermistor cable setting
proper?
Does error reoccur?
No
Yes
Yes
Connect cable set
properly again.
Turn power ON again.
Replace belt thermistor
and leave aside for 30
min. Then turn power ON
again.
Service call
918:Error
Duplex FANO
Alarm Detection
FAN error inside the Duplex.
Is the error issued again when the
power is turned on again?
Yes
Yes
Check to see if the Duplex
is properly installed.
Check to see if the FAN is
properly connected.
Replace the FAN.
Power off/on
923:Error
Black Image
Drum Lock Error
The black image drum (K-ID) does
not rotate properly.
Is the error message issued again
when the power is turned on?
Yes
Yes
Check to see if the K-ID is
properly installed.
Replace the K-ID.
Replace the K-ID motor.