Oki Data CONFIDENTIAL
44158801TH Rev.2
192 /
Figure of Serial No. label image (labeled in UK Factory)
• To specify the CU Serial Number, enter a number within 12 digits (Notice that, when the
CU Serial Number is read, it is also a number within 12 digits.)
Enter 12-digit Serial Number. Enter "4AEL4011702K."
Ser.NO. 4AEL4011702K
Lot.NO. AE47027880 A0
Made in Thailand
Configured in UK
• The CU Serial Number is output in the Printer Serial Number field of the Menu Map header
section. Therefore, after the CU Serial Number has been rewritten, it can be checked by
conducting the Menu Map print.
• The PU Serial Number is output in the Lot Number field in the bottom line of the Menu
Map header section.
6.4.3 Setup of destination
[Checking method: Menu Map Print (C5550MFP)]
Always set the destination prior to shipping out a printer or maintenance PCB, since the default
setting is OEL.
Note!
This setting is stored on the EEPROM of the SP1/TBH PCB.
1.
Setup on the operation panel: Start the printer in the maintenance mode, and set the
destination.
• Turn on the power with the MENU+ and MENU- key held down.
• "Maintenance Menu" will be displayed briefly, which will change to "OKIUSER".
• Press the MENU+ key to select the destination setting "OKIUSER" and press the ENTER
key.
• "OEL" will appear in the lower line of the LCD.
• Press the ENTER key, select the destination by operating the MENU+ or MENU- key, and
press the ENTER key.
• Press the BACK key to define the setting. "JP1"
• Press the BACK key twice, or the ONLINE key once. This will cause the printer to restart
with the destination modified.
2.
Explanation
PX735MFP are ROMs used in common for domestic and overseas markets.
This setting is stored on the EEPROM of the SP1/TBH PCB.
When the version number of the program ROM is changed, the setting will be reset to the
default value.
Make this setup when there is no destination set up or the version number of the program
has been changed.