![Oki BV1250 Technical Reference Download Page 27](http://html2.mh-extra.com/html/oki/bv1250/bv1250_technical-reference_3635968027.webp)
BV1250 Technical Reference
Maintenance and Troubleshooting
Rev. 1.0
Page 11
Table 2-2: Fault Conditions
Code
Code
Detail
Equipment
Message Type
Fault
Abbreviation
SEQ
Fault Explanation
Alarm Lamp
Comments and Corrective Action
On event
On restore
00
00
SYSTEM
Report
PowerON
00
Power ON
Off
--
No trouble.
01
Report
ResetKey
00
Reboot by reset key
Off
--
No trouble.
02
Report
Shutdown
00
Shutdown Indication
Off
--
No trouble.
03
Report
ComReboot
00
Reboot by command
Off
--
No trouble.
04
Report
FaultRst
00
Reboot by fault
Off
--
No trouble.
05
Fault
EMG Mode
00
Emergency startup
On
--
See remedies message.
06
Report
NonOFD
00
No office data
On
--
See remedies message.
07
Report
BadOFD
00
Office data error
On
--
Reinstall OFDD.VHO and restart.
08
Report
NonTerm
00
Terminal information
not registered
On
--
Register terminal information and
restart system.
09
Report
NonSYD
00
No system data
On
--
Transfer system files.
0A
Report
BadSYD
00
System data error
On
--
Transfer system files.
OB
Fault
PpTypeNG
00
PP category mismatch
On
--
Check PP category and correct
mismatch.
0C
Report
NonDNS
00
No DNS data
On
--
If is needed, transfer DNS data
0D
Report
BadDNS
00
DNS data error
On
--
Transfer DNS data
0E
Report
BadH323
00
H.323 port No. error
On
--
Correct H.323 port number.
0F
Report
BadNETDAT
00
Network address error
On
--
Correct network address
10
Fault
SOS Call
00
SOS call
On
--
Contact customer service.
11
Fault
CpuEx
00
CPU exception
On
--
Contact customer service.
12
Fault
K Fatal
00
K_fatal call
On
--
Contact customer service.
13
Fault
TF OVF
00
Infinite loop detected
On
--
Contact customer service.
15
Fault
SystemMsg
00
System message error
Off
--
No trouble.
16
Fault
00
No DSP program-1
On
--
Contact customer service
Summary of Contents for BV1250
Page 1: ...BV1250 Internet Voice Gateway TECHNICAL REFERENCE Oki Electric Industry Co Ltd...
Page 2: ......
Page 6: ...BV1250 Technical Reference Page iv Rev 1 0...
Page 10: ...Description BV1250 Technical Reference Page 2 Rev 1 0...
Page 18: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 2 Rev 1 0...
Page 22: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 6 Rev 1 0...
Page 46: ...On line Commands BV1250 Technical Reference Page 2 Revision 1 0...
Page 54: ...On line Commands Command List BV1250 Technical Reference Page 10 Revision 1 0...
Page 64: ...On line Commands Command Descriptions BV1250 Technical Reference Page 20 Revision 1 0...
Page 66: ...On line Commands Equipment BV1250 Technical Reference Page 22 Revision 1 0...