BV1250 Technical Reference
On-line Commands – Maintenance
Rev. 1.0
Page 131
Item 7-4:
REBOOT
CLASS
Maintenance command
FUNCTION
This command reboots the BV1250
CHARACTERISTICS
Reboots the BS1200
Input Parameter(s):
P1 - When omitted, reboot after all call terminate. When specified as 1, Force reboot.
Output Parameter(s):
Displays a confirmation request “Sure (Y/N)?
When
Y
or
y
is entered,
if P1=1, displays confirmation of shutdown as
“Now BV1250 System Reboot!”
if P1 omitted, displays confirmation of shutdown as
“Please wait for the end of the
calling!!”
ACCESS
REBOOT:
RS-232C and LAN
EXAMPLE(S)
REBOOT
#REBOOT
Sure(Y/N)? Y
Please wait for the end of the calling!!
...REBOOT Command End. [Thu May 28 17:00:23 1999 GW]
#
#REBOOT 1
Sure (Y/N)? y
Now BV1250 System Reboot!
ERRORS
None
Summary of Contents for BV1250
Page 1: ...BV1250 Internet Voice Gateway TECHNICAL REFERENCE Oki Electric Industry Co Ltd...
Page 2: ......
Page 6: ...BV1250 Technical Reference Page iv Rev 1 0...
Page 10: ...Description BV1250 Technical Reference Page 2 Rev 1 0...
Page 18: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 2 Rev 1 0...
Page 22: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 6 Rev 1 0...
Page 46: ...On line Commands BV1250 Technical Reference Page 2 Revision 1 0...
Page 54: ...On line Commands Command List BV1250 Technical Reference Page 10 Revision 1 0...
Page 64: ...On line Commands Command Descriptions BV1250 Technical Reference Page 20 Revision 1 0...
Page 66: ...On line Commands Equipment BV1250 Technical Reference Page 22 Revision 1 0...
Page 105: ...BV1250 Technical Reference Command Reference Maint Console Commands Revision 1 0 Page 61...
Page 180: ...On line Commands Maintenance BV1250 Technical Reference Page 136 Rev 1 0...
Page 198: ...On line Commands FXO Interface BV1250 Technical Reference Page 154 Rev 1 0...