On-line Commands – Reports
BV1250 Technical Reference
Page 122
Revision 1.0
Table: Disconnection from Originating Terminal (H.245)
Value
Meaning
Detail
Corrective Action
11222
H.245 TCP connection closed
--
Try call later
Table: Disconnection from Originating Terminal (H.323)
Value
Meaning
Detail
Corrective Action
11301
Failed queue transfer
--
Try call later
11302
Insufficient resource
--
Try call later
11303
Insufficient memory
--
Try call later
11304
Failed H.245 task create
--
Try call later
11305
Failed numbering
--
Check office data
11306
Line busy
--
Try call later
11307
Trunk busy
--
Try call later
Table: Disconnection from Originating Terminal (Line control)
Value
Meaning
Detail
Corrective Action
11401
Dial error (voice/fax access number)
Voice/Fax access number incorrect
Correct unit office data
11402
Dial error (GK,DNS information)
--
Try call later
11403
Insufficient PBREC resource
--
Try call later
11404
Illegal error
--
Reboot BV1250 Gateway
11405
Used line
--
Correct office data
11406
Failed up-link
--
Check network
11407
Password error FXO
--
Check office data/enter correct
password
Table: Disconnect from own Terminal (Voice control)
Value
Meaning
Detail/ masure
12001
Disconnect by send FIFO over flow
recall after a while
12002
Disconnect by receive FIFO over flow
recall after a while
12003
Disconnect by not received voice packets
Check network
12004
Normal disconnection
--
12005
Control busy
recall after a while
12006
Disconnect by software error
Contact dealer or customer service
Table: Disconnect from own Terminal (FAX control)
Value
Meaning
Detail/ masure
13000
Normal disconnection
--
13001
FAX line busy
recall after a while
13002
Illegal FAX modem
Reboot BS1200 Gateway or
Change FAX board
Table: Disconnect from own Terminal (DNS control)
Value
Meaning
Detail/ masure
14001
Failed DNS search
Check office data and dns data
14002
DNS socket error
recall after a while
14003
DNS resource busy
recall after a while
14004
Difference translation mode
Check translation mode GK or DNS
14005
No response ARQ
Check GK data
recall after a while
14006
Received ARJ (address translation NG)
Check numbering
Check remote terminal
Summary of Contents for BV1250
Page 1: ...BV1250 Internet Voice Gateway TECHNICAL REFERENCE Oki Electric Industry Co Ltd...
Page 2: ......
Page 6: ...BV1250 Technical Reference Page iv Rev 1 0...
Page 10: ...Description BV1250 Technical Reference Page 2 Rev 1 0...
Page 18: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 2 Rev 1 0...
Page 22: ...Maintenance and Troubleshooting BV1250 Technical Reference Page 6 Rev 1 0...
Page 46: ...On line Commands BV1250 Technical Reference Page 2 Revision 1 0...
Page 54: ...On line Commands Command List BV1250 Technical Reference Page 10 Revision 1 0...
Page 64: ...On line Commands Command Descriptions BV1250 Technical Reference Page 20 Revision 1 0...
Page 66: ...On line Commands Equipment BV1250 Technical Reference Page 22 Revision 1 0...
Page 105: ...BV1250 Technical Reference Command Reference Maint Console Commands Revision 1 0 Page 61...
Page 180: ...On line Commands Maintenance BV1250 Technical Reference Page 136 Rev 1 0...
Page 198: ...On line Commands FXO Interface BV1250 Technical Reference Page 154 Rev 1 0...