43502101TH Rev.1
43 /
Oki Data CONFIDENTIAL
2.3.24 Cassette Guide R Assy
(1) Remove the paper cassette.
(2) Remove the upper cover assy (see 2.3.1).
(3) Remove the lower base unit (see 2.3.4).
(4) Remove two screws
1
, and remove the beam plates
2
.
(5) Remove the cassette guide R Assy
3
by shifting it in the direction of arrow.
(6) Remove the earth plate
4
and the cassette lock spring
5
.
Note :
Be careful not to touch (or rotate) the DC motor thoughtlessly. Rotating the DM motor
counterclockwise removes the eject spring. (Refer to 2.3.9.)
5
2
1
1
3
4