
43502101TH Rev.1
29 /
Oki Data CONFIDENTIAL
2.3.10 Motor Assy
(1) Remove the upper cover assy (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face up stacker assy (see 2.3.8).
(4) Remove the lower base unit (see 2.3.4).
(5) Remove the DC Motor (see 2.3.5).
(6) Remove the four screws
2
and remove the bracket-Motor
1
from the Motor bracket.
Note :
Be careful not to touch (or rotate) the DC motor thoughtlessly. Rotating the DM motor
counterclockwise removes the eject spring. (Refer to 2.3.9.)
2
1
Summary of Contents for B4500 Series
Page 1: ...Oki Data CONFIDENTIAL B4500 B4550 B4600 Maintenance Manual 032007A PRINTING SOLUTIONS ...
Page 17: ...43502101TH Rev 1 17 Oki Data CONFIDENTIAL Upper cover unit Figure 2 2 Upper cover ...
Page 85: ...43502101TH Rev 1 85 Oki Data CONFIDENTIAL 2 High Voltage Sensor Board ...
Page 88: ...43502101TH Rev 1 88 Oki Data CONFIDENTIAL 3 Power Supply Board CN2 CN101 ...
Page 171: ...Please refer to the Illustrated Parts Manual for spare part information ...