43502101TH Rev.1
31 /
Oki Data CONFIDENTIAL
2.3.12 Stacker Cover Assy
(1) Remove the upper cover assy (see 2.3.1).
(2) Remove the operator panel assy (see 2.3.3).
(3) Remove the face-up stacker assy (see 2.3.8).
(4) Remove the motor assy (see 2.3.10).
(5) Remove the reset lever R
1
.
(6) Remove the reset spring
2
from the lower base unit
3
. Remove the screw
6
, rotate the reset lever
L
4
fully in the direction of arrow A until it stops, and remove it in the direction of arrow B.
(7) Disengage the two latches from the lower base unit
3
and remove the stacker cover assy
5
.
(8) For installation, perform the removal procedure in reverse order.
Note : 1.
When reinstalling the reset lever L 4, fit it onto the guide of the lower base unit
3
, turn it
in the direction of arrow C while pressing down the shaft of back up roller, and engage the
reset lever L
4
.
2.
Be careful not to touch (or rotate) the DC motor thoughtlessly. Rotating the DM motor
counterclockwise removes the eject spring. (Refer to 2.3.9.)
5
1
A
4
B
A
C
3
6
2
4
Summary of Contents for B4500 Series
Page 1: ...Oki Data CONFIDENTIAL B4500 B4550 B4600 Maintenance Manual 032007A PRINTING SOLUTIONS ...
Page 17: ...43502101TH Rev 1 17 Oki Data CONFIDENTIAL Upper cover unit Figure 2 2 Upper cover ...
Page 85: ...43502101TH Rev 1 85 Oki Data CONFIDENTIAL 2 High Voltage Sensor Board ...
Page 88: ...43502101TH Rev 1 88 Oki Data CONFIDENTIAL 3 Power Supply Board CN2 CN101 ...
Page 171: ...Please refer to the Illustrated Parts Manual for spare part information ...