43502101TH Rev.1
152 /
Oki Data CONFIDENTIAL
3.3.2
TQSB-2 PCB
(1)
Remove the pulse motor (see 3.3.1).
(2)
Remove the connectors
Q
,
R
from the GRT PCB
P
.
(3)
Remove the screw
S
and remove the GRT PCB
P
.
Note :
Refer to Detall A in the previous page.
3.3.3
Hopping Roller Shaft Assy and One-way Clutch Gear
(1)
Follow up to step (3) of 3.3.1 and remove the hopping frame assy.
(2)
Remove the screw
1
and remove the earth plate
2
. Remove the sensor lever (T)
7
and remove
the transion spring
D
and remove the ground plate
6
. Remove the gear
3
and remove the metal
bush
5
and hopping roller shaft assy
4
.
(3)
Remove the E-ring
A
and remove the one-way clutch gear
B
on the right side of the feed roller
0
.
Note :
The metal bush
C
also comes off. Be careful not to lose it.
4
1
2
3
5
A
B
C
0
9
8
6
D
7
Shaft
The tension lever and the sensor lever need concurrent replacing.