Oki Data CONFIDENTIAL
43641601TH Rev.1
61 /
Printer does not operate normally after it is turned on
• Turn off and on the printer.
• After the power light turns on, do the other three lights turn on and off once and does the main motor start
running?
• No
Is the AC cord connected properly?
• No
Connect it properly.
• Yes
Are the cable between the main board and the low-voltage power supply connected properly?
• No
Connect the cable properly.
• Yes
Is +5 V supplied to the main board (check the voltages at the pins 3 and 2 of the CN18
connector)?
• No
Aren’t the +5 V and GND on the main board short-circuited (check the voltages at the
pins 3 and 2 of the CN18 connector)?
• No Replace the low-voltage power supply.
• Yes
Replace the board.
• Yes
Is the flexible cable of the operator panel Assy. connected to the CN9 connector of the board
and the CN1 connector of the operator panel board properly?
• No
Connect the cable properly.
• Yes
Replace the Assy. or cable.
• Did this step work?
• No
Replace the main board.
• Yes
End
• Yes
Does the Ready light stay on?
• No
Replace the main board.
• Yes
Is there a connection error with the status monitor?
• No
Take proper corrective action for the problem according to status message/problem tables (see
section 5.5.1 for taking proper corrective action).
• Yes
End
Summary of Contents for B2200
Page 1: ...Oki Data CONFIDENTIAL B2200 B2400 Maintenance Manual 151107A...
Page 15: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 15 Upper cover unit Figure 2 2 Upper cover...
Page 41: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 41 This page intentionally left blank...
Page 43: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 43 This page intentionally left blank...
Page 44: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 44 This page intentionally left blank...
Page 45: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 45 This page intentionally left blank...
Page 87: ...Oki Data CONFIDENTIAL 43641601TH Rev 1 87 4 Low Voltage Power Supply...