2.3.9
Hopping roller Assy
(1) Remove the paper feeder. (See 2.3.1.)
(2) Remove the cover assy upper. (See 2.3.2.)
(3) Remove the cover assy top. (See 2.3.4.)
(4) Remove the high voltage power supply 1/ sensor board. (See 2.3.5.)
(5) Remove the frame base. (See 2.3.6.)
(6) Remove the guide sheet. (See 2.3.6.)
(7) Remove the plate side M. (See 2.3.7.)
(8) Remove the guide paper F
and C-ring ( 7)
.
(9) Remove the C-ring ( 7)
and gear-cam
. As the knock pin
comes off at that time, be
careful not to lose it.
(10) Pull out the shaft hopping assy
to the right side and remove the hopping roller
.