2.3.10 Registration Roller
(1) Remove the paper feeder. (See 2.3.1.)
(2) Remove the cover assy upper. (See 2.3.2.)
(3) Remove the cover assy top. (See 2.3.4.)
(4) Remove the plate side M and then remove the idle gear R
and gear R
. (See 2.3.7.)
(5) Remove the washer TR
, slide the registration roller
to the right and lift up the registration
bearing
of the left side to remove it.
(As two registration bearings
come off at that time, be careful not to lose them.)