90
Table 6-1(1/10)
Category
LCD status message
Problem or status
Remedy
Controller errors
–
Normal operation cannot be ensured. Turn the power
off, then back on to restart.
–
If normal operation is not recovered by this restart
procedure, replace the main control board.
ERROR On
aaaaaaaa
Code
(nn)
Error
1~3
D~F
4
5
6
7
8
9
A
B
C
Reserved
Address Error Exception
(Load command, command fetch)
Address Error Exception
(Store command)
Bus Error Exception
(Command fetch)
Bus Error Exception
(Load command, store command)
System Call Extension
Break Point Exception
Reserved Instruction Exception
Coprocessor Unusable Exception
Arithmetic Overflow Exception
An error occurred in the controller.
n = Exception Code
aaaaaaaa = Error Address