![Oki 10i Maintenance Manual Download Page 62](http://html1.mh-extra.com/html/oki/10i/10i_maintenance-manual_3658170062.webp)
62
3.3.12 Stacker Cover Assy
(1) Remove the upper cover assy (see 3.3.1).
(2) Remove the operator panel assy (see 3.3.4).
(3) Remove the face up stacker assy (see 3.3.8).
(4) Remove the reset lever R
1
.
(5) Detach the reset spring
2
from the lower base unit
3
, turn the reset lever L
4
in the direction of
arrow
A
until it stops, and remove it in the direction of arrow
B
.
(6) Unlock two latches of the lower base unit
3
, then remove the stacker cover assy
5
.
Note :
When reinstalling the reset lever L
4
, fit it onto the guide of the lower base unit
3
, turn it in the
direction of arrow
C
while pressing down the shaft of back up roller, and engage the reset lever
L
4
.
1
3
5
4
2
4
A
A
B
C
Summary of Contents for 10i
Page 10: ...10 7 PostScript program SIMM...
Page 48: ...48 Upper cover unit Figure 3 2 Upper cover...
Page 119: ...119 Figure 6 5 Contact Power supply sensor board Contact plate for transfer roller...
Page 136: ...136 Figure 8 2 Upper cover unit 2 3 1...
Page 175: ...175 CN3 CN2 SEN2 5 2 PCB Layout OLEV 11 PCB...
Page 176: ...176 Figure 6 1 Multi Purpose Feeder 9 5 7 6 4 1 2 3 8 6 PARTS LIST...
Page 191: ...191 5 2 PCB Layout TQSB 2 PCB CONTROLLER MOTOR DRIVER SEN2 SEN1 OSC PU MOTOR...
Page 192: ...192 Figure 6 1 High Capacity Second Paper Feeder 1 2 4 3 5 6 PARTS LIST...
Page 195: ...195 SECTION1 CABINET CASSETTE ASSEMBLY 8 1 2 3 4 iv 5 6 i i iv 7...
Page 196: ...196 SECTION2 MECHANICAL ASSEMBLY 21 9 11 10 12 13 23 22 14 24 15 16 iii ii 17 19 18 20 A A B B...