73
3.3.23 Power Supply/Sensor Board and Contact Assy
(1) Remove the upper cover assy (see 3.3.1).
(2) Remove the lower base unit (see 3.3.5).
(3) Remove the M5B-PCB (See 3.3.21).
(4) Remove the transformer (see 3.3.22).
(5) Remove the AC inlet
1
from the base plate
2
.
(6) Remove the screw
3
and remove the grounding (earth) wire
4
.
(7) Remove three screws
5
, and remove the power supply/sensor board
6
and contact assy
7
together.
(8) Unlock two latches
8
, and remove contact assy
7
from the power supply/sensor board
6
.
Notes : 1.
Be careful about the sensor (paper supply) when reinstalling the lower base.
2.
Make sure that no excessive force is applied to the power supply switch.
3.
When installing the power supply/sensor onto the base plate, be careful not to bend the
base plate (it is desirable to place a block underneath it to prevent bending).
View A
View A
7
1
5
5
8
6
5
3
4
2
Summary of Contents for 10i
Page 10: ...10 7 PostScript program SIMM...
Page 48: ...48 Upper cover unit Figure 3 2 Upper cover...
Page 119: ...119 Figure 6 5 Contact Power supply sensor board Contact plate for transfer roller...
Page 136: ...136 Figure 8 2 Upper cover unit 2 3 1...
Page 175: ...175 CN3 CN2 SEN2 5 2 PCB Layout OLEV 11 PCB...
Page 176: ...176 Figure 6 1 Multi Purpose Feeder 9 5 7 6 4 1 2 3 8 6 PARTS LIST...
Page 191: ...191 5 2 PCB Layout TQSB 2 PCB CONTROLLER MOTOR DRIVER SEN2 SEN1 OSC PU MOTOR...
Page 192: ...192 Figure 6 1 High Capacity Second Paper Feeder 1 2 4 3 5 6 PARTS LIST...
Page 195: ...195 SECTION1 CABINET CASSETTE ASSEMBLY 8 1 2 3 4 iv 5 6 i i iv 7...
Page 196: ...196 SECTION2 MECHANICAL ASSEMBLY 21 9 11 10 12 13 23 22 14 24 15 16 iii ii 17 19 18 20 A A B B...