4.2.5 Load Sense Control Programs (44x, 45x)
Program Item Range
Description
440
1 to 100
Program 5: Pressure Point 2 Preset
441
1 to 100
Program 5: Delta Pressure Preset
442
1 to 100
Program 5: Pressure Limit Preset
443
0 to 5
Program 5: Pressure Point 2 Source
444
0 to 5
Program 5: Delta Pressure Source
445
0 to 5
Program 5: Pressure Limit Source
446
1 to 5
Program 5: Pressure Point 1 Source
447
0 to 1
Program 5: Program Output Destination
448
0 to 100
Program 5: KP
449
0 to 100
Program 5: KI
450
1 to 100
Program 6: Pressure Point 2 Preset
451
1 to 100
Program 6: Delta Pressure Preset
452
1 to 100
Program 6: Pressure Limit Preset
453
0 to 5
Program 6: Pressure Point 2 Source
454
0 to 5
Program 6: Delta Pressure Source
455
0 to 5
Program 6: Pressure Limit Source
456
1 to 5
Program 6: Pressure Point 1 Source
457
0 to 1
Program 6: Program Output Destination
458
0 to 100
Program 6: KP
459
0 to 100
Program 6: KI
Table 6: Load Sense Programs Configuration
Function Programs 5 and 6 provide for Load Sense Control. Program 5 is configured in program
items 440 through 449 from the Program 5 Form. Program 6 is configured in program items 450
through 459 from the Program 6 Form.
Pressure Point 2 Preset
: The Pressure Point 2 Preset allows for direct numeric input for the
control program. The preset is configured as a percentage, with 0% being equivalent to a 0VDC
input signal and 100% being equivalent to a +10VDC signal.
Delta Pressure Preset
: The Delta Pressure Preset allows for direct numeric input for the control
program. The preset is configured as a percentage, with 0% being equivalent to a 0VDC input
signal and 100% being equivalent to a +10VDC signal.
Pressure Limit Preset
: The Pressure Limit Preset allows for direct numeric input for the control
program. The preset is configured as a percentage, with 0% being equivalent to a 0VDC input
signal and 100% being equivalent to a +10VDC signal.