Adjustments and checks before use
13
5.2.2
Loading the screws
1.
Open the upper cover.
2.
When the chamber plates are at their lowest position, load screws up to 2 to 3 mm below
the rail groove surface.
3.
Check that the screws are not loaded so as to cover the upper portion of the inclined
plates.
CAUTION:
Do not overload the chamber with screws otherwise it may cause a malfunction
or damage the machine.
5.2.3
Turning ON the power
1.
Plug the attached AC adapter into the main body and power outlet.
2.
When the power switch is turned ON, the power switch lamp lights up. The scooping block
starts to move up and down. The rail starts to vibrate, and the escaper starts rotating.
3.
Screws move along the rail towards the rotating escaper which selects one screw at a
time.
4.
The escaper rotates and deposits the selected screw at the pickup site.
5.
At this moment, the sensor detects a screw and the screw sensor LED lights up and then
the operation stops.
6.
When a screw is picked up, the sensor detects this, and the sensor LED light goes off and
the machine resumes operation.
CAUTION:
Do not use any AC adapter other than the one included with this unit, as it may
cause damage.