7000 SERIES INDICATORS
EN 75
The Prompt setting determines the sequence in which the operator is prompted to enter the tare weight and sample
quantity.
Options are Tare-Sample and Sample-Tare. The default is Tare-Sample.
Auto Clear APW
The Auto Clear APW setting determines whether the average piece weight value (APW) will be cleared when the
scale returns to zero, or if the APW will be retained for the next counting sequence. Settings are Enabled and
Disabled (the default).
Display
Line 1, Line 2
These parameters determine what is displayed on the two lower lines of the display. Both lines have the same
options
– Disabled (the default), ID, Description and APW.
Menu Keys
The Menu Keys parameters determine which functions will be accessible from the Operator Menu. Each of the
keys is Disabled by default.
If the feature accessed by the menu key must be enabled or configured separately, such as the ID Table,
enabling the menu key will display the icon in the Operator Menu, but will not give access to the feature.
ID Table
When Enabled, the Operator will be able to access the ID Table to retrieve stored tare and APW values for a
product.
Reports
When Enabled, the Operator will be able to generate a report of the records in the ID Table to view and print.
Sample/APW Select
When Enabled, the Operator will be able to switch from the sampling mode of operation to manual entry of an APW
value mode when prompted for Sample?.
ID Memory
ID Table
When the ID Table is Enabled, stored tare and APW values in the ID Table can be recalled by ID for a quick
counting sequence.
Totalization
This parameter appears only if the ID Table is enabled. When Totalization is Enabled, the terminal stores the total
number of pieces counted and the number of transactions for each ID in the ID Table. This parameter is Disabled
by default.
Clear on Print
This parameter appears only if the ID Table is enabled. Clear on Print may be Automatic (the default), Manual or
Disabled. When Automatic is selected, after the ID Table report is printed, the counter and totals fields will be reset
to 0. When Manual is selected, the Operator can choose to clear the counter and totals fields by pressing
CLEAR
when viewing the ID Table report. If Disabled is chosen, the counter and total fields cannot be reset in the Reports
view of the Operator menu.
ID Table
When this branch is selected, the first record in the ID Table is displayed. Each record occupies a single screen. A
blank screen indicates the ID Table is empty. The following functions are accessible from this view: