7000 SERIES INDICATORS
EN 55
3.5.5
Maintenance
A detailed view of the Maintenance branch is shown in Figure 3-17. This view indicates all the parameters in the
Maintenance branch. Each of these setup parameters are described in this section.
Figure 3-17: Maintenance Branch Menu Structure
Display Test
The Display Test screen displays all dots “on” when first accessed. After three seconds, all dots turn “off”. This
cycle will continue until the
LEFT
navigation key is pressed to return to the menu.
Keyboard Test
The Keyboard Test screen enables testing of the terminal keys, including Scale function keys, Navigation keys and
Numeric keys.
Press any key and the screen will display a graphic for that key. When testing is complete, press the
LEFT
navigation key to return to the menu.
Scale
Scale diagnostics setup screens include Load Cell Output, Calibration Values and Statistics.
Load Cell Output
The Load Cell Output screen displays the current number of counts (active value) for the scale. These are raw
counts and do not take into consideration the zero or span factors.
Press the
LEFT
navigation key to return to the menu.
Calibration Values
Summary of Contents for 7000 Series
Page 1: ...7000 Series Indicators Instruction Manual T72XW...
Page 2: ......
Page 3: ......
Page 4: ......
Page 87: ...7000 SERIES INDICATORS EN 81...
Page 96: ...EN 90 7000 SERIES INDICATORS...
Page 133: ......