Stability
Using V-sensing with long load line and high-capacity combinated could cause problems
because it operates as a part of voltage feedback root as filter.
This might cause problems in stability with output because of power supplies fast
response time. This unstable root will be feedback and make another problems
to power supply.
To reduce these problems, please follow steps below :
▌Make load lead line & sensing lead line as short as you can.
▌twist load lead line.
▌Connect sensing lead line safely to the load.
Power supply's programming feedback is a part of root, might cause problems
by using V-Sensing.
▌DO NOT connect load lead line to sensing TERMINAL.
Connecting Remote Voltage Sensing
Be careful with + - terminal when you connect load and sensing terminal for V-Sensing
If you connect load to sensing terminal, it might become unregulated condition.
The actual value of voltage & current can be different from displaying voltage & current.
It might damage the good.
Note
Remove Metal Short-Bar on output and sensing terminal to connect V-sensing.
If you stop using V-sensing, put the Metal short-bar back in to output and sensing terminal.
- 20 -