3-6. Programming Under Voltage Limit(UVL)
Users are able to change 0V to maximum voltage. However if user input voltage in UVL,
from this point users are able to change UVL voltage to maximum voltage.
UVL Level Value below can be different.
▌Power Switch ON
Check "**OUTPUT OFF**" Mode is displayed after input Power ON.
▌Before setting-up UVL, voltage limit should be higher than UVL setting value.
Therefore, set-up voltage first.
▌Use cursor key to move on to voltage range, and use encoder switch to
change the voltage value.
Voltage cannot rise more than the Protection Level in Protection (OVP/UVL
will be displayed and voltage will be set-up protection level value
/OVL) If it tries to rise more than protection level, "PROTECTION LIMIT"
will be displayed and voltage will be set up protection level value.
▌Press PROTECT Key to set-up UVL Level.
LCD Display Description
PROTECT> 1.OVP
▌Use right cursor key to move on to UVL Menu.
LCD Display Description
PROTECT> 3.UVL
▌
Press PROTECT Key once more in
"
PROTECT> 3.UVL
" condition.
LCD Display Description
UVL SET> 0.000V
▌Use cursor key to change the value.
▌Rotate encoder switch to change the level value.
UVL Level cannot rise more than present setting value which prevents
p
g
p
users mistake.
▌When it is done, press PROTECT Key to save.
LCD Display Description
Changed
Return to previous page when above message is displayed.
To cancel
▌To cancel, press I/O LOCAL Key or wait for 10 seconds.
Wait 10 sec
LCD Display Description
Cancel…
Read reference "1-6. Check after Power ON" "Earliest Setting Value"
Note