EX Series Operating Manual
6-4. LAST STATE
▌When you turn on the power supply, you can select the default state of output DC power.
▌Function.
> DISABLE
When selected this mode, boot the power supply to original default value.
For the safety, recommend this mode.
For the safety, recommend this mode.
When you turn on, appears "OUTPUT OFF" display and you press the
"OUTPUT" key, appears "00.00V 00.00A" display
> SAFETY
When you turn on the power supply, appears "OUTPUT OFF" display.
But if you press the "OUTPUT" key, recall the last state voltage/current
value. If you set the power supply in "10.50V, 40A", the power supply
save this value and when you press "OUTPUT" key, the power outputs it.
> FULLY
Recall the state before you turn off fully.
If you set the voltage 12.00V, current 40.00A, and turn off the power, and
turn on the power, after run the self-test, recalls befor(appears "12.00V
00.00A and output state is on.
Last State Operating.
▌Power switch on in a pressing "FACTORY" key.
▌Power switch ON
▌When appearing "1. user-mem clear" message, release "FACTORY" key.
In a pressing
▌Enter to "2. last state" mode by using cursor key.
▌In other to set, press the "FACTORY" key one more time.
LCD Display
disable
Release
▌Set the "SAEFTY" mode by using cursor key.
LCD Display
safety
▌To finish the last state mode, press the "FACTORY" key one more time.
LCD Display
done
≫ Related remote interface command
FACT:LAST-STA {DIS|SAF|FUL}
FACT:LAST-STA?
Return Value(DISABLE, SAFETY, FULLY)
Apply:
FACT:LAST-STA?
Return value : FULLY
Last state mode is "FULLY"
FACT:LAST-STA DIS
Last state became to
"DISABLE" mode.