64
Fig. 46 - SET END AL
Set End Press** Alarm,
information includes (Fig. 46):
> Graphic END AL
> Pressure value flashing with PSI (or BAR) icon
• A (hold) to scroll upward through Set Points at a rate of
8 per second from 300 to 1500 PSI (20 to 105 BAR) in
increments of 100 PSI (5 BAR)
• A (< 2 sec) to step upward through Set Points one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set A Menu
**End Pressure applies to the TMT (Transmitter) in use.
Set PO2 Alarm,
information includes (Fig. 47):
> Graphic PO2 AL with MAX and Nx icons
> Graphic ATA (atmospheres absolute) with value flashing
• A (< 2 sec) to step upward through Set Points from 1.20 to
1.60 one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set A Menu
Fig. 47 - SET PO2 AL