109
Fig. 100 - PO2 WARNING
(during Audible)
Fig. 101 - PO2 ALARM MAIN
> After Audible - NDC is restored, Up Arrow icon solid until
PO2 decreases below .20 less than the Alarm Set Point.
If PO2 continues to increase and reaches the PO2 Alarm Set
Point, the Audible sounds again.
> The PO2 value with graphic PO2 and Up Arrow icon will
flash until PO2 decreases below the Alarm Set Point.
PO2 Alarm Main,
information includes (Fig. 101) -
> Up Arrow icon, flashing until < Set Point, then solid
> Current Depth with FT (or M) icon
> PO2 value (ATA) with graphic PO2, flashing until < Set
Point, then solid
> ATR (min) when 60 minutes or less with graphic ATR and
Time (clock) icon, blank if no TMT
> Graphic GAS1 (or 2 or 3), one in use
> Pressure with PSI (or BAR) and Link icons, if Rcvr and TMT
are active, flashing when Link is lost
> Nx icon
> TLBG with NI icon
> VARI while ascending
• A (< 2 sec) to access ALTs
• S (< 2 sec) to acknowledge alarms
• S (2 sec) to access Compass
• M (2 sec) to access Gas Switching (or Bud Press Check)
• L (closure) to activate Backlight
Summary of Contents for OC1
Page 1: ......
Page 2: ......
Page 11: ...11 Welcome to OCEANIC and THANK YOU for choosing the OC1 FEATURES AND FUNCTIONS...
Page 29: ...29 WATCH MODE...
Page 43: ...43 This page intentionally left blank...
Page 47: ...47 NORM SURFACE MODES...
Page 77: ...77 DIVE MODE FEATURES...
Page 93: ...93 NORM DIVE MODES...
Page 115: ...115 GAS TMT SWITCHING AND BUDDY PRESSURE CHECK...
Page 121: ...121 DIGITAL GAUGE MODE...
Page 129: ...129 FREE DIVE MODE...
Page 145: ...145 COMPASS MODE...
Page 169: ...169 TECHNICAL DATA...
Page 179: ......
Page 180: ......