Fig. 36A - SET FO2 GAS 1
Fig. 36B - SET FO2 GAS 1
Set FO2 Gas 1,
information includes (Fig. 36A/B):
> Max Depth with MAX and FT (or M) icons, allowed for PO2
Alarm Set, blank if Air
> Graphic GAS1
> Graphic FO2 with FO2 Set Point value, flashing
> Graphic PO2 with alarm value set
> Nx icon, blank if Air
• A (hold) to scroll upward through Set Points at a rate of
8 per second from Air (default) to 21 through 50 (%) in
increments of 1%.
> The scroll will stop when A is released, or pause at 32% if
A is held depressed.
> Depress A, or keep it depressed, to resume the scroll from
32 through 50, then stop at Air (or 21%).
• A (< 2 sec) to step upward through Set Points one at a time
• M (< 2 sec) to step back through Set Points one at a time
• S (< 2 sec) to save the setting and revert to the Set F Menu
Gas 1 is the default gas on the surface prior to a new dive and
10 minutes after surfacing from dives.