background image

Sauna & Steam

Oceanic Saunas  01902 450 550  [email protected]

15

Infrared Sauna Assembly

vi.  Use the 30mm screws provided to fix down through the cross members into the slats. 

vii.  If your parts list shows you have a bench leg, add this now as shown. Use 6x 40mm Screws.

Summary of Contents for IR3030 Corner

Page 1: ...Sauna Steam Oceanic Ltd Pountney Street Wolverhampton WV2 4HX Phone 01902 450 550 sales oceanic saunas co uk www oceanic saunas co uk Infrared Sauna Assembly Manual...

Page 2: ...s 5 6 Add Door Important Wear goggles and gloves at all times whilst handling the door 5 7 Add Roof 7 8 Wiring 8 9 Audio Input AUX 11 10 Bench Assembly 12 11 Fix the bench end rails 16 12 Fix the benc...

Page 3: ...se high blood pressure diabetes or not in good health are advised to seek medical opinion before using a sauna room Do not smoke in the sauna room Avoid using the sauna room immediately after strenuou...

Page 4: ...ompletely in order to familiarise yourself with the procedure Each model of sauna has it s own dedicated parts list make sure you locate this before continuing This sauna cabin is for indoor use only...

Page 5: ...r is the same size as the full sizes panels so it can be moved around in most cabins We will show the different ways to join the door with the panels in the following points ii If you are working alon...

Page 6: ...embly iv To fix the door in between two panels or to the inside face of a side panel as the 2D drawings below vi If you want you can fix the other front panel to the door now or later when fixing the...

Page 7: ...ners to square up the wall panels pilot and counter sink holes and use 60mm screws don t screw near the cable holes iv Fix the roof panels to each other in the centres check they are flush on the insi...

Page 8: ...m screws into the two indicated holes Leave them protruding slightly so you can hang the heaters off them similar to how you would fit a picture frame or clock specified position iv The temperature se...

Page 9: ...vii Then mount the heater onto the wall Don t remove grill viii Fix at the bottom with 2 x 30mm screws 8 3 Under Bench Heaters i Pilot drill and screw 2 x 30mm screws at 700mm centres approx 200 300mm...

Page 10: ...will be supplied with a remote control to control the lights you can choose between many different colours there is also a fade mode iii Secure at the bottom with 1 x 30mm screw iv Finally Plug the pr...

Page 11: ...or example an MP3 player smart phone or stereo You could even buy a portable bluetooth receiver so you can connect wirelessly and play music from you phone without the AUX cable or MP3 Holder ii To in...

Page 12: ...olding power of the screw Note the use of a good quality PVA adhesive not supplied will improve the durability of the benches Maximum loadings Up to 1200 mm no centre support 2 x 12 5 stone people Up...

Page 13: ...cer ii Lay the 5 or 6 bench slats face down on a work bench use two pieces of scrap timber along the edges of your bench to create a square corner to work off Use small pieces of corner mould as 19mm...

Page 14: ...oceanic saunas co uk 14 Infrared Sauna Assembly iv Add the cross members two are positioned 100mm from the ends the third is centred a dimension for A can be found on your parts list v Evenly space o...

Page 15: ...0 550 sales oceanic saunas co uk 15 Infrared Sauna Assembly vi Use the 30mm screws provided to fix down through the cross members into the slats vii If your parts list shows you have a bench leg add t...

Page 16: ...se 4 x 50mm screws ii Fit the two support legs using a brad nailer as shown this can alternatively be done using a countersink and 30mm screws 12 Fix the bench i Pre dill with countersink then fix 2 x...

Page 17: ...ecific detailed information on the back rest i Layout the back rest frame as to the drawing in the parts list ii Pre drill the top rail with countersink tool iii Screw the top rail onto the uprights i...

Page 18: ...rared Sauna Assembly 14 Fix the back rest Pre drill with countersink through the end uprights at the top and bottom then fix the back rest using 4 x 40mm screws so the bottom is level with the bench i...

Page 19: ...ornice from the roof stage please continue to the next step Important Do not pin near cables ie the centre of each heater panel 15 3 Door i If you have installed the door on the end face of a side pan...

Page 20: ...vided the front facia has been machined with curves on the ends so you don t need to mitre you can just butt the other square edge trim upto it 15 4 Overlap Use 32x9mm overlap across the joints betwee...

Page 21: ...of the sauna with 25mm brads 16 3 Exterior Skirt Measure cut and fix 45 x 9mm trim around the bottom edges of the sauna with 25mm brads 16 4 External Facia Joint Overlap Measure cut and fix 32 x 9mm...

Page 22: ...o uk 22 Infrared Sauna Assembly 17 Floor Matt Assembly i Refer to the parts list for specific detailed information on the floor matt ii Pre drill holes with 4mm countersink bit iii Fix with 2 x 30mm s...

Page 23: ...in turn on the socket then turn on the switch on the RCD switch on the top of the control box 18 2 Commercial Unit All commercial units must be hard wired to an isolated mains supply and cannot be plu...

Page 24: ...rcuit Diagram N L Infrared heater element 1 3 5 7 2 4 6 8 Controller Voltage DC5V MINI Steam generator Sensor Speaker Speaker Music input socket Music Volume Fan AC230V Light AC12V M ax 40W chromo the...

Page 25: ...Display the detected temperature of steam room 10 Steam Not used 11 Fan Indicated the Fan is active not required for Oceanic IR sauna 12 Music Indicated the Speakers have been turned on 13 Light Indic...

Page 26: ...and 30 minutes for a session iv Adjusting the temperature Press the Set button twice The temperature will now start flashing Increase or decrease using the blue and red arrow keys Once correct press t...

Page 27: ...recautions i The equipment must be installed vertically ii Stop pouring water into the boiler when the high level LED light A turns on Don t let the water reach the holes in the top cover You can rele...

Page 28: ...9 Control panel 10 SUS tank 11 Water level probe 12 Steam outlet and water inlet 13 Shell 14 Heat preservation cotton 22 5 Installation i Position the steam generator on a blank wall panel at low lev...

Page 29: ...nit is set to 750W LED indicator unit is set to 1000W LED indicator generator is currently heating LED indicator generator has power LED indicator generator has overheated Overheat switch has been tri...

Page 30: ...are to be diluted 1 part aroma to 20 parts water For every 1ltr of water only add a maximum of 50ml of aroma ix Ensure you drain the steam generator after the end of your session 24 Mini Steam Generat...

Page 31: ...ty the next days and flush twice using drain Faults arising from a result of a failure to descale the generator are not covered by warranty 25 Guarantee All generators and heaters are guaranteed for 1...

Reviews: