Section 3A: Preparation
6
5. Remove fountain nose assembly.
Tool Needed: T20 Torx bit
Wires
Water Line
A. Remove 4x #10 Torx screws from the fountain.
B. Disconnect ONLY the nose assembly wires from the cold control and solenoid valve.
Leave all other wires connected to the cold control and solenoid valve. For non-
refrigerated models, unplug the unit.
C. Disconnect the water line from the bubbler inside the nose. DO NOT disconnect
from the fountain.
DO NOT REMOVE COLD CONTROL OR SOLENOID VALVE
ASSEMBLIES FROM THE FOUNTAIN.
Disconnect only the nose assembly
wires from the cold control and
solenoid valve.