Section 6: Set-Up Guide For OASIS
®
Hands-Free Bottle Filler
Electronics
• Units - Gallons
• Unfiltered unit
• Flow Meter = Rate Selected
• Filter Capacity = 1250 gallons [4731 liters] for a VersaFilter
•
•Pushbutton
•
Factory default program settings are:
• Bottle Count = 0.5L (1 Bottle)
• Flow Rate = 1.2 GPM
• 20 second maximum dispense time
•
To change the program settings, follow these steps:
•
For each model
top cap will need to be set aside until programming is complete. Remove top cap by unscrewing
two (2) T15 torx screws if needed. Remove wire tie bundling pushbutton inside bottle filler and feed it through hole in
cooler top. You can then adjust program using pushbutton through access panel of cooler.
•
Display
Action
000000000
BOTTLES REUSED
(Home Screen)
Depress button for 3 seconds to enter into the following menu settings and make changes.
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button
press) and revert back to Home Screen.
LTR/GAL
GAL
Depress button 3 seconds to change from Gallons to Liters,
or momentary press to advance to next menu.
UNFILT/FILT?
UNFILT UNIT
Depress button 3 seconds to change from Unfiltered to Filtered unit,
or momentary press to advance to next menu.
FLOW METER?
RATE SELECTED
Depress button 3 seconds to change from Rate Selected to (Flow) Meter Enabled,
or momentary press to advance to next menu.
SELECT RATE
1.2 GPM UNIT
To change flow rate, momentarily depress button to change whole gallon digit.
Hold button 3 seconds to advance to TENTHS of gallon digit.
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET 00000000
GALLON CNT
[LTR COUNT]
Depress button for 3 seconds to reset Gallon or Liter count,
or momentary press to advance to next menu.
FILT CAPAC
OF 1250 GAL
[4731 LTR]
Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 liters] for Galaxi
green filter,
or momentary press to advance to next menu.
3 sec rule?
0.5L
Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule,
or momentary press to advance to next menu.
(The 3 Sec rule increases the bottle count based on a 3 second dispense.)
Reset 00000000
BOT COUNT?
Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count,
or momentary press to advance to next menu.
Bot Filler
Set_time: 20 s
Depress button for 3 seconds to change maximum dispense time to 10, 20 or 30 seconds,
or momentary press to advance to next menu.
RUN CAL
AGAIN?
Depress button 3 seconds to run calibration again,
or momentary press to advance to next menu.
Summary of Contents for NNEBFEZ
Page 3: ...NNEBFEZ Section 2 Rough In Drawing 3...
Page 4: ...SINGLE LEVEL PREPARATION 4 Disassembly of ELKAY Cooler Wiring Water Lines...
Page 9: ...9 SINGLE LEVEL INSTALLATION Assembly of NNEBFEZ Cabinet Wiring Plumbing...
Page 21: ...21 SPLIT LEVEL INSTALLATION Assembly of Split Level NNEBFEZ Cabinet Wiring Plumbing...
Page 35: ...35...