Section 6: Split Level Preparation
23
1. Remove the fountain wrappers and noses from each unit as shown on
pages 5-6
to
prepare the units for the NNEBFEZ installation. Unplug BOTH units and shut off their
water source.
2. Begin split level assembly by disconnecting and removing any drainpipes except for the
p-trap and disconnecting the water lines between the fountain units.
Ensure water to
the units has been turned off.
3. Since the split level fountain cold tank is already pressurized, disconnect all water lines
from the solenoid valves in both the refrigerated and dummy unit. Do not discard any
water tubing.
Cover any bare terminals. Refer to
page 7
.
Solenoid to
Tee:
Disconnect
and set aside
Solenoid to
Bubbler:
Disconnect
from solenoid
valve
Tee to
Solenoid/Solenoid
to Bubbler:
Disconnect from
solenoid valve
ORIGINAL CONFIGURATION