- EN -
48
Cleaning time ʺ
Cleaning
ʺ
(
CL
)
This setting changes the duration of the cleaning cycle. If the water does not carry away all
dirt, a longer cleaning time is required. This may become necessary if, for instance, very
long drain pipes or drain pipes with many bends were installed or there is a particularly
large amount of sticky dirt (e.g. during spawning).
A longer cleaning time increases the water consumption. The default setting of 10 s is usu-
ally sufficient (corresponds to approx. a
7
/
8
drum rotation).
How to proceed:
Touch the button of the slider control and move it to adjust the time.
Adjustable range: 10 – 30 s.
Extended cleaning time "Extra Cleaning" (
EC
)
The extended cleaning time after every 20 cleaning cycles prevents larger deposits in the
dirt channel or the pipework. This ensures that the pipework is flushed out at regular inter-
vals.
However, if dirt and residue build up due to unfavourable conditions, increase the cleaning
time to flush out the pipe with additional water.
How to proceed:
Touch the button of the slider control and move it to adjust the time.
Adjustable range: 10 – 60 s.
Time-dependent cleaning "Intervall" (
ln
)
In addition to automatic cleaning, an option for time-dependent cleaning is available. This
is particularly useful for ponds containing fish. Even if there is only a small amount of dirt,
excrement is always removed from the water cycle before it leads to a build-up of nutrients.
The time-dependent cleaning cycle does not have any influence on the automatic cleaning
cycle that starts when the water level is too low. After each automatic cleaning cycle, the
time interval is reset and starts again from the beginning.
How to proceed:
Touch the button of the slider control and move it to adjust the time.
Adjustable range: 0; 3 – 60 min.
0 minutes: The function is deactivated.
Basic setting: 20 minutes (the ideal setting for most applications).
Basic settings
The control system is reset to the basic settings.
All individually set values are overwritten!
The following values are set:
Cleaning time
CL
: 10 s
Extended cleaning time
EC
: 20 s
Interval of the time-dependent cleaning
In
: 20 min
Summary of Contents for InScenio
Page 1: ...InScenio EGC Controller Home Cloud...
Page 2: ...2 A EGC0004 B EGC0005 C EGC0006 F...
Page 3: ...3 D EGC0007 F E EGC0008 F F EGC0009...
Page 4: ...4 G EGC0003 H EGC0010...
Page 7: ...DE 7 10 Ersatzteile 33 11 Entsorgung 33 Technische Daten 643 Symbole auf dem Ger t 644...
Page 36: ...EN 36 10 Spare parts 62 11 Disposal 62 Technical data 643 Symbols on the unit 644...
Page 123: ...ES 123 10 Piezas de recambio 149 11 Desecho 149 Datos t cnicos 643 S mbolos en el equipo 644...
Page 210: ...DA 210 10 Reservedele 236 11 Bortskaffelse 236 Tekniske data 643 Symboler p apparatet 644...
Page 239: ...NO 239 10 Reservedeler 265 11 Kassering 265 Tekniske data 643 Symboler p apparatet 644...
Page 268: ...SV 268 10 Reservdelar 294 11 Avfallshantering 294 Tekniska data 643 Symboler p apparaten 644...
Page 297: ...FI 297 10 Varaosat 323 11 H vitt minen 323 Tekniset tiedot 643 Laitteessa olevat symbolit 644...
Page 384: ...CS 384 10 N hradn d ly 410 11 Likvidace 410 Technick daje 643 Symboly na p stroji 644...
Page 413: ...SK 413 10 N hradn diely 439 11 Likvid cia 439 Technick daje 643 Symboly na pr stroji 644...
Page 527: ...BG 527 BG 1 0 8 30 mA...
Page 529: ...BG 529 10 555 11 555 643 644...
Page 538: ...BG 538 Seasonal Flow Control SFC SFC An Aus SFC SFC Min Med Max DFC SFC 0 100...
Page 540: ...BG 540 C 24 2 24 12 C 24 24 24 24 Er22 24 Er22 1 2...
Page 556: ...UK 556 UK 1 0 8 30...
Page 558: ...UK 558 10 584 11 584 643 644...
Page 567: ...UK 567 Seasonal Flow Control SFC SFC SFC SFC Min Med Max SFC DFC 0 100...
Page 569: ...UK 569 C 24 2 24 12 C 24 24 24 24 Er22 24 Er22 1 2...
Page 571: ...UK 571 7 1 3 ProfiLux EGC OASE EGC0020 1 2 3 iOS 2 Android 2 0 LED 100...
Page 572: ...UK 572 1 2 3 4 Scenen 1 Scene 2 Scene Scene 2 Scene 3 Scene 4 Scene 5 1 100...
Page 585: ...RU 585 RU 1 0 8 30...
Page 587: ...RU 587 10 613 11 613 643 644...
Page 596: ...RU 596 Seasonal Flow Control SFC SFC SFC SFC Min Med Max DFC SFC 0 100...
Page 598: ...RU 598 C 24 2 24 12 C 24 24 24 24 Er22 24 Er22 1 2...
Page 600: ...RU 600 7 1 3 ProfiLux EGC OASE EGC0020 1 2 3 iOS 2 2 0 100...
Page 601: ...RU 601 1 2 3 4 Scenen 1 Scene 2 Scene Scene 2 Scene 3 Scene 4 Scene 5 1 100...
Page 614: ...CN 614 CN 1 0 8 30mA...
Page 616: ...CN 616 10 642 11 642 643 644...
Page 625: ...CN 625 Seasonal Flow Control SFC SFC SFC SFC Min Med Max DFC SFC 0 100...
Page 627: ...CN 627 C 24 2 24 12 C 24 24 24 24 Er22 24 Er22 1 2...
Page 629: ...CN 629 7 1 3 EGC ProfiLux OASE EGC0020 1 2 3 iOS 2 Android 2 LED 0 LED 100...
Page 630: ...CN 630 LED 1 2 3 4 Scenen LED 1 Scene 2 Scene 2 Scene Scene 3 Scene 4 Scene 5 1 100...
Page 646: ...36425 06 18...