Q-Code User Manual
Ver. 7.0 2021/11/30
120
3.9.28.23 LVD_mVn / LVD_Max
The path “
LVD_mVn
” / “
LVD_Max
” only can be applied in
[Path]
section. When VDD matches
supported range, system will execute path once.
Supported VDD range and system path is as following:
VDD Range
NY5+
NX1 OTP
NX1 EF
<2.0V
LVD_2V0
LVD_2V2
LVD_2V0
2.0V ~ 2.2V
LVD_2V2
LVD_2V2
2.2V ~ 2.4V
LVD_2V4
LVD_2V4
LVD_2V4
2.4V ~ 2.6V
LVD_2V8
LVD_2V6
LVD_2V8
2.6V ~ 2.8V
LVD_3V2
2.8V ~ 3.0V
LVD_3V0
LVD_3V0
3.0V ~ 3.2V
LVD_3V3
LVD_3V2
3.2V ~ 3.3V
LVD_3V4
LVD_3V4
3.2V ~ 3.4V
LVD_3V6
3.4V ~ 3.6V
LVD_3V6
LVD_3V6
>3.6V
-
LVD_Max
LVD_Max
Note:
1. NY4 / NY5 / NY6 / NY7 / NY9T do not support this path.
2. Execution of PowerOn may be interrupted if this is path is triggered while power is on.
3.9.28.24 LVD_LV5
The path “
LVD_LV5
” only can be applied in
[Path]
section. When Vdd is higher than 4.1V, system
will execute this path once.
Note: NY4 / NY5 / NY5+ / NY6A / NY7 / NY9T / NX1 do not support this path.
Ex.
[Path]
PowerOn:
LVD_LV5: PA=5
;PA output 5 when voltage is higher than 4.1V.
3.9.28.25 LVD_LV4
The path “
LVD_LV4
” only can be applied in
[Path]
section. When VDD is between 4.1V~3.6V,
system will execute this path once.
Note: NY4 / NY5 / NY5+ / NY6A / NY7 / NY9T / NX1 do not support this path.
Ex.