39
2.
Go to the manual screen and ensure that all the
zones required for calibration are turned on.
3.
If you are running a calibration cycle, set the
duration of the watering cycle to an appropriate
time e.g. 10 mins.
2
3
4
4.
To calibrate go to the settings page and locate the
calibr
ate fl ow heading.
5.
Press ‘Start Calibration’ and let the system
water through the manual cycle. This will record
the average fl ow for each zone. The calibration
process will run through the entire manual cycle
until completed.
5
WaterMe Flow Calibration
Before operation WaterMe must fi rst be calibrated to record the average fl ow rate for each zone. Calibration will tell your WaterMe
controller what the average fl ow rate is for each zone. This data is used during normal watering to advise you if a change has
occurred i.e. major leak in the valve and/or sprinklers. Before calibrating ensure that your valve system is free from leaks and
operates correctly. Please note that this process only needs to be completed if a fl ow sensor is installed.
After calibration your irrigation system will be tuned to detect any potential leaks, reduction or increases in fl ow which will
allow you to shut
off your irrigation system remotely if an error is detected.
1.
To calibrate your irrigation system you must fi rst
add all your zones within the zone confi guration
screen.
SECTION 7.2