38
Web Interface: Settings Screen
4
12
10
6
8
2
1
11
13
3
5
9
7
No.
Settings
Description
1
Turn on if a fl ow sensor is being used
WaterMe comes packaged with a 1” fl ow sensor. It is advisable to
install for maximum water monitoring features.
2
Mist duty cycle parameter
Determines how much water will fl ow per interval of time. You
can set the on/off
time interval for the water to fl ow through the
irrigation system
3
Set the fl ow rate tolerance for a triggered error
condition*
If the water fl ow within your irrigation system falls below the
tolerance % you will be notifi ed with an alarm. This will allow you to
investigate in the event there is an error in the system
4
Adjust master delay time before a zone starts
The master delay time is the time between the master valve
activating and Zone 1 activating
5
Set the delay time between each zone
The zone delay time is the time between a previous zone turning off
and the next zone being activated
6
Flow sensor calibration*
The Nymet fl ow sensor is automatically calibrated to 1.0. If you
are using a non standard fl ow sensor you can adjust this value to
calibrate the fl ow e.g. 0.5 to divide the fl ow by 50% time
7
Turn on if moisture sensor is connected
WaterMe allows you to connect a moisture sensor if required
8
Turn on if rain sensor is connected
WaterMe allows you to connect a rain sensor if required
9
Select between 24VAC of DC latching valves
WaterMe allows you to run both 24VAC valves (typical) or DC
latching valves
10
Select the time zone for the device
Depending on your location you can set the time zone WaterMe
is located in. This is required so the WaterMe server can manage
your irrigation system based on your location.
11
Set the default action for alarm errors
Access to a submenu to select the default course of action in the
event of an error in the system. This is required for WaterMe to
take a course of action in the event of an error.
12
Start fl ow calibration*
Allows the system to calibrate the average fl ow running through
the system for each zone.
13
Clears previous fl ow rate data*
WaterMe accumulates total fl ow data and for individual zones. This
button allows you to reset the counter back to 0.
*These settings will only take eff ect if a fl ow sensor is installed.
!
Note
•
For further explanation and description
of weather settings please go to Settings
Explanation Section 9.2