23
DC24 MOIS VPP RAIN FLW2 FLW3
DC24 GND GND FLW1 GND GND
Wire Colour
Sensor Terminal Input
Red
VPP
Yellow
FLW1
Black
Common/Ground
No.
Input
Connection Type
1
Master Valve
The master valve is the primary valve in the system. It is advisable to install a master valve as
it will provide extra insurance in the event the other valves fail. The master valve input can be
confi gured to operate a pump.
2
Flow Sensor
It is recommended to install a fl ow sensor after the master valve but before the other solenoids
in the irrigation system. This will allow the fl ow sensor to monitor the amount of water fl ow
during each watering cycle for each water outlet. A fl ow sensor can be used to detect any
potential leaks in the irrigation system by monitoring water fl ow. WaterMe includes a 1” fl ow
sensor.
3
Solenoids Valves
One solenoid valve is required to control the watering of one zone. The number of zones
required will depend on a number of variables such as input pressure and fl ow, each sprinkler
consumption, and watering requirements for individual plants.
!
Note
•
The installation provided should be used as an example only. Actual installation confi guration may vary based
on individual situation
Wiring Diagram Example
Flow Sensor Connection