TWO POST SPL10000
Nussbaum Automotive Solutions, LP | 1932 Jordache Court, Gastonia, NC 28052 | 704.864.2470 | Email:
| us.nussbaumlifts.com
18
TROUBLE-SHOOTING
If the Lift does not work properly, refer to the following trouble-shooting guide. If the problem cannot be resolved,
call Technical Service at 704.864.2470.
PROBLEM
POTENTIAL CAUSE
REPAIR OPTIONS
Motor does not start
No power supply, or feed line is cut
Check the power supply at the facility breaker
box and the power supply box.
Motor is defective
Call technical service.
Top Limit Switch is engaged or
defective
If engaged: loosen actuator mechanism.
If defective: replace switch.
Motor starts, Lift does not move
Vehicle is too heavy
Check vehicle for empty weight. Unload
unnecessary weight from vehicle.
Oil level is too low
Lower Lift and fill oil reservoir. Check for
leakage. Call Technical Service if leakage is
observed.
Defective Hydraulic Valve
Check for leakage. Call Technical Service if
leakage is observed.
Gear Pump is defective
Check for leakage. Call Technical Service if
leakage is observed.
Leakage in the Hydraulic System
Check for leakage. Call Technical Service if
leakage is observed.
The Lift will not lower
Lift is resting on the mechanical locks Press the Raise Button until the locks are
clear, engage the Lock Release Lever.
An obstacle is restricting the Lift from
being lowered
Press the Raise Button until the obstacle is
freed. Remove the obstacle.
Lowering valve is defective
Call Technical Service.
Lock Release Cable is broken or
defective
Call Technical Service or your manufacturing
representative to purchase a new Lock
Release Cable.
The Lift lowers unexpectedly
Lowering valve is defective
Call Technical Service.
REPLACEMENT PARTS
ONLY USE NUSSBAUM ORIGINAL EQUIPMENT PARTS TO REPAIR THE LIFT
CALL NUSSBAUM PARTS DEPARTMENT AT 1-704-864-2470
Summary of Contents for SPL 10 Series