21
2.12 Drive calculation
• NTN-SNR provides, as a customer service, the assembling of drives provided by the customer.
• NTN-SNR assumes no warranty for the calculation of the provided drive.
• Calculations of drives are carried out exclusively by the respective drive manufacturer.
• The reason for this is that NTN-SNR does not have all necessary calculation tools and basic data of these drives.
2.13 Selection of Linear Axis with toothed belt drive for 90 ° tilt mounting
(wall mounting)
For Linear Axis with a toothed belt drive in a 90 ° tilted arrangement (wall mounting), the toothed belt can be displaced downwards
during operation by the gravity force to the flanged pulley. For this reason, we recommend not to exceed the stroke limit length
specified in Table 2.2.
If the mounting of the Linear Axis is provided in this position, this information is required in the order description.
During operation, the centered run of the toothed belt must be checked together with the maintenance of the Linear Axis specified
in Chapter 4.7.
Series
Type
Stroke limit length [mm]
AXC
AXC40Z
1500
AXC60Z
2000
AXC80Z
2500
AXC100Z
3000
AXC120Z
3000
AXDL
AXDL110Z
2000
AXDL160Z
2500
AXDL240Z
3000
AXF
AXF100Z
3000
AXS
AXS280Z
3000
Table 2.2 ____ Stroke limit length for Linear Axis with toothed belt drive
Summary of Contents for AXC100Z
Page 1: ...www ntn snr com NTN SNR LINEAR MOTION LINEAR AXIS With You ...
Page 8: ...6 ...
Page 242: ...240 Notes ...