LinMot Installation Guide
9 Power Supply Requirements
Motor Power Supply
The calculation of the needed power for the Motor supply is depending on the
application and the used motor. The nominal supply voltage is 72- 80 VDC. The
possible range is from 24 to 85VDC, for UL from 30 to 85 VDC.
ATTENTION:
The motor supply can rise up to 95 VDC when braking.
This means that everything connected to that power supply needs a
voltage rating of 100 VDC. (Additional capacitors, etc…). Due to high
braking voltage and sudden load variations of linear motor
applications,
only specially designed power supplies can be used
.
Compatible Power supplies
:
Item
Description
Art. No.
T01-72/420
72VDC, 15A peak, 420VA, 3x400VAC
0150-1966
T01-72/420-US
72VDC, 15A peak, 420VA, 3x230VAC
0150-1967
T01-72/900
72VDC, 30A peak, 900VA, 3x400VAC
0150-1842
T01-72/900-US
72VDC, 30A peak, 900VA, 3x230VAC
0150-1843
T01-72/1500
72VDC, 2x30A peak, 1500VA, 3x400VAC
0150-1844
T01-72/1500-US
72VDC, 2x30A peak, 1500VA, 3x230VAC
0150-1845
S01-72/500
72VDC, 500W, 750W peak, 1x100..120VAC/200..240VAC
0150-1874
S01-72/1000
72VDC, 1000W, 2000W peak, 3x380..500VAC
0150-1872
For compatibility with other power supplies, contact
Signal Power Supply
The logic supply needs a regulated power supply of a nominal voltage of 24 VDC.
The voltage must be between 22 and 26 VDC.
Current consumption:
min. 200mA (no load on the outputs)
typ. 1.1A
(all 10 outputs “on” with 100mA load and /Break with no load)
max. 2.1A
(all 10 outputs “on” with 100mA load and /Break with 1A load)
NTI AG / LinMot
®
www.LinMot.com
Page 17/20
E
1
2
0
0
In
s
ta
lla
ti
o
n
G
u
id
e