LinMot Installation Guide
10 Regeneration of Power / Regeneration Resistor
There are two possibilities to deal with power regeneration:
Option A:
Connect an additional capacitor to the motor power supply. It is
recommended to use a capacitor >= 10’000 µF
(install capacitor close to the power supply!)
Option B:
Install a regeneration resistor to X1 (RR+ and RR-). The threshold
value of the voltage depends on the used motor voltage power supply.
The max. threshold value must not exceed 88 VDC.
For UL applications, use option A.
Item
Description
Art. No.
Capacitor
Capacitor 10’000
µ
F / 100 V
0150-3075
Regeneration Resistor
R01-10/60
(10 Ohm, 60 W)
0150-3088
Regeneration Resistor
RR01-10/150
(10 Ohm, 150 W)
0150-3090
11 Ordering Information
Item
Description
Art. No.
E1250-PL-UC
POWERLINK Servo Controller
72VDC/32A
0150-1760
E1250-PN-UC
PROFINET Servo Controller
72VDC/32A
0150-1762
E1250-EC-UC
ETHERCAT Servo Controller
72VDC/32A
0150-1763
E1250-SC-UC
SERCOS III Servo Controller
72VDC/32A
0150-1764
E1250-IP-UC
ETHERNET IP Servo Controller
72VDC/32A
0150-1761
E1230-DP-UC
PROFIBUS-DP Servo Controller
72VDC/32A
0150-1766
E1200-GP-UC
GENERAL PURPOSE Servo Controller 72VDC/32A
0150-1771
RS232
configuration cable
AC01-RJ45/Df-2.5-RS1
0150-2143
12 International Certifications