NSC Sicherheitstechnik GmbH
32/69
14.08.2013
Lange Wand 3
B01050 B01060 Operating Installation Manual Solution F1 20130814.doc
33719 Bielefeld
Version S040A13.08
54
Autom.controlling Status
Output : 001 Normal
↓
+1
↑
-1 Selection ->+10 <--10
>001 Output 001 Main board
002 Output 002 Main board
003 Output 003 Main board
Cancel Enter
Autom.controlling Status
Output : 001 Normal
↓
+1
↑
-1 Selection ->+10 <--10
>001 Output 001 Main board
002 Output 002 Main board
003 Output 003 Main board
Cancel Settings Function Event
Automatic Control: internal OC Outputs
Please select the OC output which shall be configured
by the cursor keys :
↑
,
↓
: Marker ">" one line up / one line down
<-, -> : Marker ">" 10 lines up / 10 lines down
or type the number of the OC output directly by using
the keypad and confirm this by "OK”.
Underneath the grey line "Selection" the FCB
indicates where the selected outputs are. OC outputs
1 to 16 are on the main board, any further outputs are
on the additional loop cards :
OC outputs 01 – 16 : on Main board
OC outputs 17 – 24 : on loop card / convent. card 1
OC outputs 25 – 32 : on loop card / convent. card 2
etc.
The selected output has to be confirmed by "OK” or
by F4 ("Enter"). After this the last line of the LC
module looks like the example left.
Press F2 ("Settings")
Jump to Menu
104
(Menu 104 to assign on/off functions to the outputs)
Press F3 ("Function")
Jump to Menu
105
(Menu 105 to link the outputs with fixed standard
functions of activation)
Press F4 ("Event")
Jump to Menu
106
(Menu 106 to configure cause and effects events
when the output has to activate)
55
Autom.controlling Status
Relay : 001 Normal
↓
+1
↑
-1 Selection ->+10 <--10
>001 Relay 001 Main board
002 Relay 002 Main board
003 Relay 003 Main board
Cancel Enter
Automatic Control: 4 internal Relays
This configuration menu relates to 4 internal relays on
the main board.
The operation is he same as described in Menu
54
.
56
Autom.controlling Status
Power Output : 001 Normal
↓
+1
↑
-1 Selection ->+10 <--10
>001 Power Output1 Main board
002 Power Output2 Main board
003 Power Output3 Main board
Cancel Enter
Automatic Control: 3 monitored Power
outputs
This configuration menu relates to 3 internal power
outputs on the main board.
The operation is he same as described in Menu
54.
57
Output module
Segment :
Address :
Output :
Cancel
Automatic Control: Output modules (loop)
This configuration menu relates to the output modules
on the loops.
Please type the loop number (”Seg.”) and the output
module’s address and confirm every line by "OK”.
Because some of the modules (B02450/51-00 and
B02460/61-00) have two separate outputs you can
select the output (1 or 2) in the line "Output” and
confirm by "OK”.