PROCESSOR – BOOSTER AND CYLINDER
III OPERATING PRINCIPLE
Fig. 2
CYLINDER EXTEND (NO LOAD)
When the cylinders (c11) are extended
(
jaw close
) and no load (
material to be
crushed or sheared
) is encountered, oil
is directed from the carrier control valve
(k7) to the base end of the cylinders by
way of the pilot check valve (c20) in the
booster assembly. When there is no
load condition, hydraulic pressure is low
and no boosted pressure is required.
c11
Jaw Cylinder
c20
Pilot Check Valve Assembly
k7
Carrier Control Valve
fl1
High Pressure Hydraulic Flow
fl2
Low Pressure Hydraulic Flow