131
-
TROUBLESHOOTING
MEASURING OPERATING PRESSURES
Tools and equipment required:
(For carriers with an NPK hydraulic installation kit installed).
Pressure gauge (g8f): 5000 psi
(350 bar)
.
Test port adapter (g20): to fit #4 SAE female port in NPK shut-off valve (k4).
Test hose (t81): 5000 psi
(350 bar)
rated
RELIEF VALVE CHECKING AND SETTING PROCEDURE
NPK Hydraulic Installation Kits provide shut-off valves (k4) with test ports (k8) in both
the jaw open (m4) and close lines (m3). Install pressure test hoses in both test ports.